DATA CENTER COOLING | ROOM, RACK AND SERVER COOLING

As data centers get larger and more powerful, reliable thermal management becomes an even more mission-critical requirement. The methods for achieving this are changing along with the industry as the demand for efficiency and sustainability continues to increase. Honeywell offers Solstice EC 11, climate-friendly cooling fluid to reduce direct CO2E impact up to 99.9% while providing high performance thermal management using cold plates and thermosyphons.

INTRODUCING SOLSTICE® EC

Two-Phase Cooling Technology for Datacenter Cooling

 

Two phase fluids can lower CO2e impact of datacenters significantly through improved cooling by bringing fluid up to the chip, using heat pumps to re-use heat generated and generating clean energy through organic rankine cycle. Solstice fluids can power all three applications. As we move cooling from room to rack to server, Honeywell fluids can help at every stage. Improved performance in a pumped cold plate, passive thermosyphon and immersion cooling is what we aim for.

Solstice® EC 11

Solstice® EC11 (R-1233zd) can cool high performance electronics more effectively and efficiently than traditional air-cooling and can serve applications in telecom, datacenter, consumer electronics, power electronics, among others.
Read More

Solstice® EC 21

Solstice® EC21 (R-1234ze) can cool high performance electronics more effectively and efficiently than traditional air-cooling and can serve applications in telecom, datacenter, consumer electronics, power electronics, among others.
Read More

Solstice® EC 40

Solstice® EC40 (R-515B) can cool high performance electronics more effectively and efficiently than traditional air-cooling and can serve applications in telecom, datacenter, consumer electronics, power electronics, among others.
Read More
Downloads (2)
File Type
Language
Introducing Solstice® EC | sell sheet
File Type
pdf
Language
English
Solstice® EC Fluids for Two-Phase Liquid Cooling
File Type
pdf
Language
English
Downloads (6)
File Type
Language
Ultra-Low GWP Heat Transfer Fluids for Pumped Two-Phase Cooling - ITherm 2020
File Type
pdf
Language
English
Low-Pressure Heat Transfer Fluids for Pumped Two-Phase Cooling - ITherm 2021
File Type
pdf
Language
English
Experimental Characterization of a Server-Level Thermosyphon for High-Heat Flux Dissipations, Amalfi, et al. (Nokia paper, 2020)
File Type
pdf
Language
English
Solstice® EC Fluids for Two-Phase Liquid Cooling
File Type
pdf
Language
English
The Future of Datacenter Cooling:Passive Two-Phase Cooling, Amalfi, et al. (Electronics Cooling, May 6, 2020)
File Type
pdf
Language
English
Ultra-Compact Micro-Scale Heat Exchanger for Advanced Thermal Management In datacenters, Amalfi, Et Al.(Interpack2020, Oct. 27-29, 2020)
File Type
pdf
Language
English